The Stiebel Eltron DHC 4/6-2 Trend Point-of-Use Electric Tankless Water Heater - 200062 features Stiebel Eltron’s Direct Coil™ heating technology. Engineered for efficiency and reliability, this 240V/208V, 4.5/6.0 kW tankless water heater is designed without a tank, incorporating an internal thermostat for optimal temperature control. Its Direct Coil™ system not only offers self-cleaning capabilities for unparalleled resistance to limescale buildup but also ensures rapid heating, minimal heat retention, and enhanced overall performance. Specifically crafted for hassle-free installation and use without the need for user adjustments, the DHC 4/6-2 Trend model eliminates the need for screens or temperature settings. Instead, it relies on precise power output selection based on the required flow rate and temperature increase, complemented by an internal jumper that allows for the selection among four output temperatures, simplifying installation and ensuring optimal operation.

Features:

  • Direct Coil heating system’s proven and trouble-free technology self-cleans for increased limescale resistance
  •  Switchable kW power output means each model can cover more applications
  •  Ideal for many commercial applications including bathrooms, break rooms, utility sinks, or a single shower
  •  Heats water on demand, for endless hot water as long as it is needed but model size must be carefully matched to the application for proper operation
  •  Electronic self-modulation technology ensures the least amount of electricity needed is used
  •  Sleek European design is considerably smaller than a tank, requires no venting, and allows space-saving installation close to the point-of-use
  •  Direct Coil heating system provides fast heat-up and response
Carbon-neutral shipping with Shopify Planet
Carbon-neutral shipping on all orders
6,282kg
shipping emissions removed
That's like...
16,081
miles driven by an average gasoline-powered car
We fund innovations in...
Direct Air Capture
Bio Oil
Mineralization

Specifications

ModelDHC 3/3.5-1 TrendDHC 4/6-2 TrendDHC 8/10-2 TrendDHC 12/15-2 Trend
Item no.200060200062200063200064
Phase - 50/60 Hz1
Voltage120 V240 V208 V240 V208 V240 V208 V
Wattage 1, Jumper Position 1 [Low] / 2 [High]3 kW / 3.5 kW3.8 kW / 6 kW2.9 kW / 4.5 kW7.2 kW / 9.6 kW5.4 kW / 7.2 kW12 kW / 14.4 kW9 kW / 10.8 kW
Amperage, Jumper Position 1 [Low] / 2 [High]25 A / 29.2 A15.8 A / 25 A13.9 A / 21.7 A30 A / 40 A26 A / 34.6 A50 A / 60 A43.3 A / 52 A
Min. Recommended Circuit Breaker Size (2), Jumper Position 1 [Low] / 2 [High]25 A / 30 A20 A / 25 A15 A / 25 A30 A / 40 A30 A / 35 A50 A / 60 A50 A / 60 A
Min. Recommended AWG Wire Size (3) , Jumper Position 1 [Low] / 2 [High]10/2 / 10/212/2 / 10/214/2 / 10/210/2 / 8/210/2 / 8/28/2 / 6/28/2 / 6/2
Minimum Water Flow To Activate Unit0.264 gpm (1.0 l/min)
Max Flow Rate (GPM) @ 42°F0.4 GPM / 0.5 GPM0.5 GPM / 0.85 GPM 1 GPM / 1.4 GPM 1.7 GPM / 2 GPM 
Max Flow Rate (GPM) @ 52°F0.5 GPM / 0.6 GPM0.7 GPM / 1 GPM 0.9 GPM / 1.5 GPM 1.4 GPM / 2.3 GPM 
Max Flow Rate (GPM) @ 62°F1 GPM / 1.4 GPM1.3 GPM / 1.7 GPM 1.8 GPM / 2.3 GPM 2.7 GPM / 3.6 GPM 
Max Flow Rate (GPM) @ 72°F1.7 GPM / 2 GPM2.2 GPM / 2.6 GPM 2.9 GPM / 3.5 GPM 4.6 GPM / 5.5 GPM 
Weight5.5 lb (2.5 kg)
DimensionsHeight 14 1/8" (360 mm) x Width 8" (202 mm) x Depth 4 5/16" (109 mm)
Nominal Water Volume0.07 gal (0.277 l)
Max. Permissible Inlet Temperature149 °F (65 °C)
Maximum Permissible Pressure145 psi (10 bar)
Water Connections (3)½" NPT

DHC 3/3.5-1 Trend and 4/6-2 Trend ship with pressure compensating flow-reducer/aerators that must be installed. 

1 Factory default setting is jumper position 2 [high] 

2 Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers. 

3 Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load. 

 

These are recommendations. Check local codes for compliance if necessary.