The Stiebel Eltron Accelera 300 E Heat Pump Water Heater represents the pinnacle of water heating technology, engineered in Germany and leading the European market for over 30 years. Unlike traditional models, this heat pump water heater is designed to operate primarily on its heat pump mechanism rather than relying on a backup element, ensuring maximum efficiency. It offers an impressive reduction in hot water costs by up to 80%, providing both comfort and the lowest possible energy expenditure. Moreover, the Accelera 300 E is backed by a robust 10-year warranty, emphasizing its reliability and long-term performance.
* Installation location has to have a minimum size of 10´ x 10´ x 8´.
Order Processing and Shipping
Rise ships manufacturer direct. We work hard so you receive your product(s) as quickly as possible. Learn more about our order processing & shipping times here.
General Data | Accelera® 220 E | Accelera® 300 E |
---|---|---|
Item No. | 233058 | 233059 |
Operating temperature range | 42°F to 108°F (6°C to 42°C) | |
DHW temperature | 149 °F (65°C) | |
Air flow rate | 324 CFM | |
Sound power level* | 60 dB | |
Sound pressure level* @ 3.3 feet (1 m) | 52 dB(a) | |
Capacity | 58 gal (220 l) | 79.8 gal (302 l) |
Refrigerant / fi lling weight | R134a / 850 g | R134a / 900 g |
Height | 60 7/8˝ (1545 mm) | 75¼˝ (1913 mm) |
Diameter | 27 1/8˝ (690 mm) | |
Height of unit when tilted incl. packing | 74 1/8˝ (1895 mm) | 87¾˝ (2230 mm) |
Weight dry | 264.5 lb (120 kg) | 297.6 lb (135 kg) |
Weight wet | 748.5 lb (339.5 kg) | 956.6 lb (433.9 kg) |
Water connection | 1˝ male NPT | |
Condensate connection | 3/4˝ male NPT to ½˝ barbed elbow | |
Safety condenser | Wraps around outside | |
Operating pressure, water side | 87 psi (600 kPa) | |
High pressure cutoff, refrigerant side | 348.1 psi (2.4 MPa) | |
Electrical Data & Performance | ||
Voltage / Frequency | 220–240 V / 60 Hz | |
Circuit breaker | 15 A | |
Rated current compressor & fan | 2.7 A | |
Rated power consumption compressor and fan (2) | 650 W | |
Rated power, booster heater | 1500 W | |
Heating output, heat pump3 | approx. 1700 W | |
Energy factor | 3.05 | 3.39 |
DOE est. yearly energy usage / cost | 1040 kWh | 1289 kWh |
DOE est. yearly energy cost | $169 | $155 |
First hour rating | 50.3 gal (190.4 l) | 74.2 gal (280.8 l) |
* Sound Power Level measures the sound energy emitted by a source. Sound Pressure Level (SPL) measures the sound level (loudness) at a distance from the source. SPL varies depending on the acoustic environment and the accuracy of the measurement device.
1 Tamb = 107.6 °F (42 °C) Twater = 149 °F (65 °C) / 240 V
2 Test point to DIN 8497 at 59 °F (15 °C) air temperature, 70% rel. humidity and 113 °F (45 °C) water temperature.
3 Test point at 59 °F (15 °C) air temperature, 70% rel. humidity, heating up water from 59 °F (15 °C) to 149 °F (65 °C), according to EN 255 T3, 240 V / 60 Hz
"Hybrid" Water Heaters | Accelera Heat Pump Water Heaters | |
---|---|---|
Their most efficient mode provides the greatest savings they're capable of. Water heaters operates only with the heat pump.
"Hybrids" must be set to the correct mode in order to either save energy or provide comfort. | Heat Pump Mode | This is the main setting. Accelera is engineered to satisfy 90% of hot water needs through the use of the heat pump alone. In cases of high demand, one specially-designed electric "booster" element is located at the very top of the tank. Positioned near the hot water draw point, the element has been designed and engineered to run as little as possible so that comfort is maintained and savings maximized. |
Two standard electric elements activate for fast water temperature recovery. System allows heat pump to work once demand has been met via electric elements. | Hybrid Mode | Accelera is designed to satisfy hot water needs without having to pick a setting. There is nothing to remember to choose i order to have both comfort and savings. |
Twi standard electric elements activate sooner and stay on longer than in their "hybrid" mode. | High Demand Mode | Accelera is engineered to work as a harmonious whole to offer comfort and savings without having to ask, "what setting do I need to choose today?" In cases of extraordinarily high demand the Accelera 220 E has a user accessible booster function that will engage the booster element. |
Heat pump is disabled and, just like a standard electric tank, two electric elements heat the water. "Hybrids" don't have active defrost and must enable this mode so the evaporator can defrost. This mode is also selected if the heat pump fails. | Standard Mode | Accelera was engineered so that the heat pump doesn't need to be disabled for a defrost cycle. We also engineered for reliability. Why pay extra for a heat pump water heater if you're just going to end up with a standard electric tank? |
Water heater maintains a very low temperature in the tank then reheats the water the day before you return. | Vacation Mode | Our super-insulated tank keeps water hot in an Accelera during a 2-week vacation for less than $4. No one has t worry if vacation mode was set to wake up on the correct day. |