Skip to content

Stiebel Eltron DHC-E 12/15-2 Plus Point-of-Use Electric Tankless Water Heater - 200056

1 Review
SKU 200056
Original price $359.00 - Original price $359.00
Original price
$359.00
$359.00 - $359.00
Current price $359.00
Availability:
in stock

The Stiebel Eltron DHC-E 12/15-2 Plus Point-of-Use Electric Tankless Water Heater - 200056 features the revolutionary Direct Coil™ heating technology. This model, designed for efficiency and convenience, operates at 240/208V with a 12.0/14.4 kW power range, ensuring immediate hot water without the wait. It stands out with its Advanced Flow Control™, which promises consistent water temperatures even when demand exceeds capacity by intelligently adjusting the water flow. Equipped with a large digital display for easy temperature setting, it also offers unique functionalities like a cost-savings calculator, real-time capacity monitoring, and preset temperature settings. Safety is paramount, evidenced by its scald guard and control lock-out features, making it a sophisticated choice for modern homes seeking both performance and peace of mind.

Features:

  • Direct Coil heating system’s proven and trouble-free technology self-cleans for increased limescale resistance
  •  Switchable kW power output means each model can cover more applications
  •  Ideal for many commercial applications, including bathrooms, break rooms, utility sinks, or a single shower
  •  Heats water on demand, for endless hot water as long as it is needed, but model size must be carefully matched to the application for proper operation
  •  Electronic self-modulation technology ensures the least amount of electricity needed is used
  •  Sleek European design is considerably smaller than a tank, requires no venting, and allows space-saving installation close to the point-of-use
  •  Direct Coil heating system provides fast heat-up and response
  •  Advanced Flow Control ensures constant water temp no matter what - no cold water "surprises"
  •  Large backlit interactive display shows temperature, flow rate information, cost savings calculator, and more
  •  2 temperature preset buttons for quick adjustments
Carbon-neutral shipping with Shopify Planet
Carbon-neutral shipping on all orders
6,282kg
shipping emissions removed
That's like...
16,081
miles driven by an average gasoline-powered car
We fund innovations in...
Direct Air Capture
Bio Oil
Mineralization

Specifications

Model DHC-E 3/3.5-1 Trend DHC-E 4/6-2 Trend

DHC-E 8/10-2 Trend 

DHC-E 8/10-2 Plus

DHC-E 12/15-2 Trend 

DHC-E 12/15-2 Plus

Item no.200057200061

200058 (Trend) 

202145 (Plus)

200059 (Trend) 

200056 (Plus)

Phase - 50/60 Hz1
Voltage120 V240 V208 V240 V208 V240 V208 V
Wattage (1) , Jumper Position 1 [Low] / 2 [High]3 kW / 3.5 kW3.8 kW / 6 kW2.9 kW / 4.5 kW7.2 kW / 9.6 kW5.4 kW / 7.2 kW12 kW / 14.4 kW9 kW / 10.8 kW
Amperage, Jumper Position 1 [Low] / 2 [High]25 A / 29.2 A15.8 A / 25 A13.9 A / 21.7 A30 A / 40 A26 A / 34.6 A50 A / 60 A43.3 A / 52 A
Min. Recommended Circuit Breaker Size (2) , Jumper Position 1 [Low] / 2 [High]25 A / 30 A20 A / 25 A15 A / 25 A30 A / 40 A30 A / 35 A50 A / 60 A50 A / 60 A
Min. Recommended Awg Wire Size (3) , Jumper Position 1 [Low] / 2 [High10/2 / 10/212/2 / 10/214/2 / 10/210/2 / 8/2 10/2 / 8/28/2 / 6/28/2 / 6/2
Minimum Water Flow to Activate Unit0.264 gpm (1.0 l/min)
Max Flow Rate (GPM) @ 42°F0.4 GPM / 0.5 GPM0.5 GPM / 0.85 GPM1 GPM / 1.4 GPM1.7 GPM / 2 GPM
Max Flow Rate (GPM) @ 52°F0.5 GPM / 0.6 GPM0.7 GPM / 1.o GPM0.9 GPM / 1.5 GPM1.4 GPM / 2.3 GPM
Max Flow Rate (GPM) @ 62°F1.0 GPM / 1.4 GPM1.3 GPM / 1.7 GPM1.8 GPM / 2.3 GPM2.7 GPM / 3.6 GPM
Max Flow Rate (GPM) @ 72°F1.7 GPM / 2.0 GPM2.2 GPM / 2.6 GPM2.9 GPM / 3.5 GPM4.6 GPM / 5.5 GPM
Weight5.5 lb (2.5 kg)
DimensionsHeight 14 1/8" (360 mm) x Width 8" (202 mm) x Depth 4 5/16" (109 mm) 
Nominal Water Volume0.07 gal (0.277 l)
Max. permissible inlet temperature149 °F (65 °C)
Maximum Permissible Pressure145 psi (10 bar)
Water Connections (3)½" NPT

 

DHC-E 3/3.5-1 Trend and 4/6-2 Trend ship with pressure compensating flow-reducer/aerators that must be installed. 

  1. Factory default setting is jumper position 2 [high]
  2. Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers.
  3. Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load. 

 

These are recommendations. Check local codes for compliance if necessary

 